Inspect The Unpiggable

Skip navigation
  • Technology
  • Services
    • Corrosion Detection
    • Corrosion Rate
    • All Services
  • Resources
    • Cases
    • Blog
    • Events
    • Glossary
    • FAQ
  • About
    • Contact
    • Company
    • Careers
      • Jobs

NEW: Onshore Inspections

The Flux

A robust handheld system for corrosion detection and 3D mapping of unpiggable pipelines.

Discover the Flux →
corrosion-rate

NEW Service

Corrosion Rate

Know how fast every coating defect corrodes, in µm/year, validated against excavations.

See how it works →

FREE: Whitepaper

Corrosion or not?

How CMI separates protected steel from actively corroding steel, without excavation.

Download →

BOOK A DEMO

Skip navigation
  • Technology
  • Services
    • Corrosion Detection
    • Corrosion Rate
    • All Services
  • Resources
    • Cases
    • Blog
    • Events
    • Glossary
    • FAQ
  • About
    • Contact
    • Company
    • Careers
      • Jobs
Book a demo →

What Is Ductile Iron Pipe Inspection?

Ductile iron pipe inspection assesses the condition of water and gas mains made of ductile iron. The material replaced grey cast iron from the middle of the 20th century because it is tougher and bends before it breaks. Its weak point is corrosion from outside, which eats through the wall at single points.

Talk to an expert

On this page

At a glanceFailureFrom above groundFAQ

Ductile Iron Inspection at a Glance

MaterialCast iron with graphite in nodules, which makes it tough
Typical damageExternal pitting through the wall, leaking joints
ProtectionZinc coating, bitumen, polyethylene sleeving or cement mortar, depending on age
Classic basisAge, material and burst history
From above groundCMI condition assessment with the main in operation

How Does Ductile Iron Pipe Fail?

Ductile iron does not shatter like grey cast iron. It fails mostly through external pitting that grows through the wall and ends as a leak. How fast this happens depends on the soil and on the condition of the outer protection. Two mains of the same age can therefore be in very different condition, which is why age alone is a poor basis for renewal.

How Does CMI Assess Ductile Iron Mains?

EMPIT feeds a small alternating current into the pipe and measures its magnetic field from the surface, along the full length of the main. The assessment covers grey cast iron, ductile iron and steel, coated or uncoated.

  • Corrosion assessment: every detected location is classified into a corrosion rate class with a corrosion rate in µm per year and given a recommended action
  • Soil resistivity profile: continuous along the route, showing the sections where the soil promotes corrosion
  • 2D and 3D pipeline scan: position, bends and depth of cover along the whole line

EMPIT has mapped more than 1,000 km of cast iron and ductile iron pipelines in 3D. Water Main Condition Assessment from Above Ground describes the deliverables.

Frequently Asked Questions

What is the difference between ductile iron and cast iron pipe?

In grey cast iron the graphite forms flakes, which makes the material brittle. In ductile iron it forms nodules, which makes the pipe tougher and able to deform before it breaks.

How long does ductile iron pipe last?

There is no fixed service life. Soil, outer protection and loads decide, which is why a condition assessment says more than the age.

Can ductile iron mains be inspected without excavation?

Yes. CMI assesses ductile iron mains from above ground while they stay in operation.

Start with a Pilot Section

Planning a renewal programme, or unsure about one critical main? Send us the length, material and location. We will tell you whether CMI fits and what a pilot section would look like.

Get in touch

Sources

  • EMPIT, Water Main Condition Assessment from Above Ground
  • AWWA Manual M77, Condition Assessment of Water Mains

Related terms

Cast Iron InspectionPitting CorrosionPipeline CorrosionDepth of CoverCMIWater Main Condition Assessment

Read more

30. September 2026

Water Main Condition Assessment from Above Ground: Replace It, or Run It for Another 20 Years?

Read more →

13. October 2026

Unpiggable Pipeline Inspection from Above Ground

Read more →

Go back to list

Logo EMPIT GmbH

Inspect The Unpiggable

+49 (0) 30 51656040
info@empit.com

Skip navigation
  • Home
  • About
  • Technology
  • All Services
  • Contact
Skip navigation
  • Blog
  • Events
  • Careers
  • Glossary
  • FAQ
Skip navigation
  • Linkedin
  • Twitter
  • Youtube
  • Instagram


© 2026 EMPIT GmbH  |  All rights reserved.

Skip navigation
  • Legal Notice  |
  • Privacy Policy  |
  • Cookies

We use cookies to give you the best possible experience on our website and to improve our communication with you. We only use the data for which you have given us your consent, with the exception of the cookies that are absolutely necessary for the functionality of this website. For more information, please see our privacy policy. Make your choice here:

You can change your consent at any time by clicking on the Cookie Settings link in your footer.

Protects against cross-site request forgery attacks.

Retention period: This cookie remains only for the current browser session.

Saves the current PHP session.

Retention period: This cookie remains only for the current browser session.

Cookie from Google for website analytics. Generates statistical data about how visitors use the website. https://policies.google.com/privacy?hl=de

Provider: Google Ireland Limited, a transfer of data to Google LLC, USA, cannot be excluded.
Retention period: 2 years
Technical name: _ga,_gat_gtag_G-BJSNZ3WRY8,_gid
Provider: Provider: Google Ireland Limited, a transfer of data to Google LLC, USA, cannot be excluded."
Retention period: 2 years
Legal Notice Privacy Policy