
NEW: Onshore Inspections
The Flux
A robust handheld system for corrosion detection and 3D mapping of unpiggable pipelines.
Discover the Flux
NEW: Onshore Inspections
A robust handheld system for corrosion detection and 3D mapping of unpiggable pipelines.
Discover the Flux
NEW Service
Know how fast every coating defect corrodes, in µm/year, validated against excavations.
See how it works
FREE: Whitepaper
How CMI separates protected steel from actively corroding steel, without excavation.
Download
A DCVG survey is the usual way to locate coating defects on a buried pipeline. In a benchmark on a 36-inch gas pipeline of Transitgas AG in Switzerland, DCVG located two coating defects on a 1,433 m section. Current Magnetometry Inspection (CMI) confirmed both and located more than 20 in total, including a 1 cm² test coupon that DCVG did not detect.
| Pipeline | Gas transmission pipeline of Transitgas AG in Switzerland, built in 1973 |
| Test section | From the southern bank of the Rhine to the Wallbach station, about 1,433 m |
| Pipe | 36 inch (914.4 mm) diameter, 12.7 mm wall thickness |
| Coating | Bituminous coating, about 5.5 mm thick |
| Cathodic protection | On potential about -2 V (CSE), not shifted for the survey |
| Reference | Test coupon with a steel surface of 1 cm², buried at a depth of about 80 cm |
| DCVG result | 2 coating defects located |
| CMI result | Both DCVG defects confirmed, more than 20 coating defects located in total, test coupon located |
Direct Current Voltage Gradient (DCVG) is a coating survey. It uses the current of the cathodic protection system as its source and measures the voltage gradient in the soil above the pipeline with two electrodes. Where current enters the steel through a coating defect, a gradient appears. DCVG shows where the coating is damaged. It does not show whether the steel at the defect is corroding.
On pipelines with a high quality coating the defects are small, and small defects produce small voltage gradients. To make them visible, a DCVG survey is often run with an increased potential swing, which means a clearly more negative on potential. The defects found this way are then excavated and recoated. In practice only very few of these excavations turn out to be necessary. In most cases the cathodic protection was working and the steel showed no active corrosion [1].
CMI takes a different route. A signal generator feeds an alternating inspection current into the pipeline, and a detector with up to 70 sensors records the magnetic field of that current from above ground in all three directions. Where current leaves the pipe through a coating defect, the field changes. The on potential of the cathodic protection stays where it is.
The test section belongs to a gas transmission pipeline of Transitgas AG that was built in 1973. It runs from the southern bank of the Rhine to the Wallbach station and is about 1,433 m long. The pipe has a diameter of 36 inches (914.4 mm) and a wall thickness of 12.7 mm. It is protected by a bituminous coating about 5.5 mm thick.
The on potential was about -2 V against a copper/copper sulphate electrode. It was not shifted further negative for the survey, to avoid any risk of AC corrosion or coating disbondment. For an objective check of both methods, a test coupon with a steel surface of 1 cm² was buried at a depth of about 80 cm. Both methods surveyed the same section. The DCVG data came from the cathodic protection contractor.
DCVG located two coating defects, one near the start and one near the end of the section. CMI found a defect at both positions, so the two methods agree on these two.
CMI located more than 20 coating defects in total. One of them is the test coupon at about 800 m. Its position and its size were known, which makes it the reference of the benchmark. CMI located it. DCVG did not detect it under the given measurement conditions [1].
More indications do not mean more excavations. CMI assesses every coating defect it finds, so the operator digs where the steel is at risk.
This assessment is the core of EMPIT's Corrosion Detection service.
To check a CMI result that DCVG had not confirmed, one location was excavated on another pipeline in Switzerland, this one with a three-layer polyethylene (3LPE) coating. CMI had indicated two separate coating defects of about 0.1 cm² each.
Both were there. When the coating was removed, it turned out to be disbonded over an area of about 12 cm² around them. The steel showed minor metal loss and voluminous corrosion products. Very small coating defects, voluminous corrosion products, a large disbonded area and limited metal loss are the typical picture of AC corrosion [1, 2].
The finding matters for the way surveys are run. More negative on potentials can accelerate AC corrosion [2]. A method that locates small coating defects without shifting the potential avoids this risk during the survey.
CMI records more than coating defects. From the same magnetic field data it calculates the position and depth of cover of the pipe in three dimensions, with a resolution of 1 cm along the line. At the excavated location CMI showed a pipe bend that should not have been there according to the pipe book. The excavation confirmed the bend.
Position data of this quality also show where a pipeline has moved. From the displacement, the bending strain on the pipe can be derived. This matters in particular when a pipeline is converted to hydrogen.
The comparison was published in the journal 3R, issue 01|2024 [1].
DCVG measures the voltage gradient in the soil with two electrodes and uses the cathodic protection current as its source. CMI feeds an alternating inspection current into the pipeline and measures its magnetic field from above ground. Both locate coating defects. CMI also assesses the corrosion activity at each defect and maps the position of the pipe.
No. DCVG is a coating survey. It locates coating defects, but it does not show whether the steel at a defect is corroding.
Small coating defects produce small voltage gradients in the soil. In the benchmark the on potential was not shifted further negative, and under these conditions DCVG did not detect the 1 cm² coupon. CMI located it.
No. CMI works with its own inspection current. The on potential stays at its normal setting and the pipeline stays in service.
Send us the length, diameter and location of your line. We tell you whether CMI fits and what a pilot section would look like.
Sources