The DVGW has published the final report of the research project NEMEK (G 202329) — "Neue Methodik zur externen Korrosionsbewertung an kathodisch geschützten Rohrleitungen" (New Methodology for External Corrosion Assessment on Cathodically Protected Pipelines). Conducted with six major European gas transmission operators — GASCADE Gastransport GmbH, ONTRAS Gastransport GmbH, Open Grid Europe GmbH, Westnetz GmbH, Swissgas AG, and Thyssengas GmbH — this independent research validates Current Magnetometry Inspection (CMI) as the first above-ground survey method capable of determining the corrosion state at individual coating defects.
Standard above-ground survey methods such as DCVG (Direct Current Voltage Gradient), CIPS (Close Interval Potential Survey), and Intensive Measurement (IM) have been industry practice for decades. They reliably identify coating defects — but they share a fundamental limitation: they cannot determine whether active corrosion is occurring at a detected defect, or whether the steel is protected by a passive calcareous film.
The NEMEK report quantifies the consequence: Intensive Measurement (IM) produces a false negative rate of 68.4 % for E_IR-free assessment, and CIPS achieves only 64.9 % true positive rate. In practice, this means that up to 95 % of excavations triggered by conventional methods are operationally unnecessary — causing significant cost and disruption without improving pipeline safety.
The NEMEK project evaluated CMI across real operating pipelines of six gas transmission operators. The core metric — protective layer formation (Deckschichtbildung) at coating defects — was assessed using CMI's patented frequency-dependent spread resistance analysis. The results:
37 excavations on the real operating pipelines additionally confirmed CMI's performance:
These findings confirm that CMI is the only above-ground method that combines coating defect detection with reliable corrosion state classification in a single inspection run.
Where conventional methods stop at detecting a coating holiday, CMI determines the electrochemical condition of the steel beneath. By applying a multi-frequency AC current (2 Hz – 2 kHz) and analysing the frequency-dependent spread resistance and phase angle at each defect, CMI distinguishes between:
Crucially, CMI does not disrupt cathodic protection during measurement — unlike DCVG, which requires potential swings of up to 25 V that shift the pipeline's E_on in the cathodic direction, increasing the risk of AC corrosion and coating disbondment.
The NEMEK final report provides independent, peer-reviewed evidence that CMI fundamentally changes the economics and reliability of external corrosion direct assessment (ECDA). For pipeline operators, this means:
The NEMEK final report (DVGW research project G 202329) is available through the DVGW. To discuss how CMI-based inspection can improve your pipeline integrity programme, contact our team.