GEOMETRY ASSESSMENT

Identification of anomalies in the geometry of the pipeline. Our customers use Geometry Assessment for pipelines, which have bad or incomplete documentation.

Information collected by EMPIT is used to identify the location and size of various restrictions in the line, thus allowing our clients to make informed decisions: For example, whether to proceed with feasibility studies and reconstruction of pipelines in order to make them piggable. Or to proceed with EMPIT’s time and money saving inspection services, including integrity and coating inspection solutions.

 

TECHNICAL SPECIFICATIONS FOR GEOMETRY AND MAPPING

FOR A PIPELINE DEPTH (AXIS) < 2M

MAX. ERROR PIPELINE DEPTH
< 20 mm

MAX. ERROR XYZ MAPPING
< 20 mm

BEND DETECTION
max. 20 D radius

MAX. ERROR HORIZONTAL BEND DIAGNOSIS (RADIUS)
0.5 D

MAX. ERROR HORIZONTAL BEND DIAGNOSIS (ANGLE)
1 °

MAX. ERROR VERTICAL BEND DIAGNOSIS (RADIUS)
1.0 D

MAX. ERROR VERTICAL BEND DIAGNOSIS (ANGLE)
5 °

DETECTION OF ILLEGAL TAPS
Possible

WALL THICKNESS | DIAMETER | MEDIUM | GRADE OF STEEL | PRESSURE | OUT OF SERVICE
No limitations

Inspection distance
Not limited

It’s for a reason that we are amongst Germany’s Top 100 innovators. Because our mission is to overcome these inspection challenges and, together with our clients, continuously improve the safety and reliability of all pipelines.